N/AL.8.240.300.02 7/97
Typical Performance Characteristics
B64G
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Ordering Information. Models listed include ISO G threads, knob adjustment, automatic drain, metal bowl, 40 µm element, relieving
diaphragm and 0,3 to 10 bar (5 to 150 psig) outlet pressure adjustment range* without gauge.
† Typical flow with 10 bar (150 psig) inlet pressure, 6,3 bar (90 psig) set pressure and a 1 bar (15 psig) droop from set.
Port Size Model Flow
†
dm
3
/s (scfm) Weight kg (lb)
G1/4 B64G-2GK-AD3-RMN 30 (64) 1,71 (3.80)
G3/8 B64G-3GK-AD3-RMN 76 (161) 1,69 (3.76)
G1/2 B64G-4GK-AD3-RMN 106 (225) 1,66 (3.69)
G3/4 B64G-6GK-AD3-RMN N.A. 2,02 (4.49)
Alternative Models
B 6 4
-
G
★ ★
-
★★ ★ ★
Port Size Substitute
1/4
"
2
3/8
"
3
1/2
"
4
3/4
"
6
Threads Substitute
PTF A
ISO Rc taper B
ISO G parallel G
Diaphragm Substitute
Relieving R
Non relieving N
Element Substitute
5 µm 1
25 µm 2
40 µm 3
Adjustment Substitute
Knob K
T-bar T
Bowl Substitute
Metal with liquid level indicator D
Guarded Transparent P
-
★★ ★
Drain Substitute
1/4 turn manual M
Automatic A
Gauge Substitute
With G
Without N
Outlet Pressure Adjustment Range* Substitute
0,3 to 4 bar (5 to 60 psig) F
0,3 to 10 bar (5 to 150 psig) M
0,7 to 17 bar (10 to 250 psig) S**
* Outlet pressure can be adjusted to
pressures in excess of, and less than,
those specified. Do not use these units to
control pressures outside of the specified
ranges.
** Units with 17 bar (250 psig) adjustment
range are available only with the T-bar
adjustment; therefore substitute
T
at the 7th
digit and
S
at the 12th position.
Commenti su questo manuale